A low voltage electrical installation is similar to an industrial process for electricity distribution
and needs a supervisory and monitoring system that is able to increase reliability and optimize
management.
To achieve integration between conventional plant engineering techniques and control sys-
tems for the purpose of running, controlling and monitoring civil and industrial installations in a
centralized and automatic way, one can consider the electrical installation as being affected by
two flows:
n a main flow (energy flow) formed by the power and energy supplied to the users and loads
of an installation through the line conductors and control and protection devices;
n an information flow (digital flow) formed by all the information, data and commands required
to control and manage the installation.
The supervisory system handles the flow of information that transits through the communica-
tion network.
A single family of moulded-case circuit-breakers up to 3200 A
Solutions for energy measurement and communication
1
4
1
1
4
2
2
In this type of installation, the circuit-breaker acts as both sensor and actuator. As a sensor,
it collects sensitive information and data and sends them to the supervision system. As an
actuator, it executes the command received from the control device (e.g. PC or PLC).
These characteristics are of particular importance since they meet the growing demands for
circuit-breaker integration into latest generation networks (Smart Grid).
XT4 250 Ekip E-LSIG 3p - Ekip Com, MOE-E
Due to its integrated current and voltage sensors, the Ekip E elec-
tronic trip unit can measure both the main electrical quantities and
the most advanced Power quality indicators; such as Power Factor,
Harmonic distortion and THD.
By means of the trip unit and Ekip Com Communication module,
the MOE-E motor operator allows the digital signals from the su-
pervision and control system to be used and converted into power
signals for operating the circuit-breaker in the remote mode.
T5 400 PR223DS 3p - MOE-E, VM210
Due the conventional L, S, I and G protection functions, the
PR223DS trip unit also allows the main electrical quantities to
be measured.
Using the VM210 accessory and without the need for voltage
transformers, the user can obtain both the current values and
the voltage, power and energy values in the local and remote
modes via a supervising and control system.
T7M 1600 PR332/P 3p - PR330/V, PR330/D-M
The SACE PR332 trip unit for Tmax T7 provides a sophisticated
and flexible protection system. Fitted with the PR330/D-M internal
dialogue module, PR332/P becomes a smart protection, measur-
ing and communication device based on the Modbus
®
RTU
protocol. Module PR330/V measures and processes the neutral
and phase voltages, then transfers these data to the protection
release so that a set of protection and measuring functions can be
implemented.
HMI030
This device, which can be installed on the front of the switchboard,
comprises a graphic display showing all the measurements and
alarms/events of the trip unit. Thanks to its high-level accuracy, the
device is a valid substitute for conventional multimeters without the
need for current/voltage transformers.
XT2 160 Ekip LSIG 3p - Ekip Com, Ekip Display
Ekip Display is a unit that can be applied to the front of the ad-
vanced electronic trip unit and shows the current values, voltage
values, alarms and programmed protection and communication
parameter settings.
Trip units
Frame [A]
160 250 400 500 630 800 1000 1600 2500 3200
LSI (Advanced electronic trip unit) Tmax XT2-XT4-T4-T5-T6-T7-T8
LSIG (Advanced electronic trip unite) Tmax XT2-XT4-T4-T5-T6-T7-T8
Functions
Frame [A]
160 250 400 500 630 800 1000 1600 2500 3200
Energy measurement Tmax XT4-T4-T5-T6-T7-T8
Supervision and Monitoring Tmax XT4-T4-T5-T6-T7-T8